Installation Guide
Table Of Contents
- MDS-G4000/MDS-G4000-L3 Series Quick Installation Guide
- Package Checklist
- Default Settings
- Panel Layouts
- Dimensions
- Ethernet Modules (Hardware Rev.2.0.0 and above)
- Power Modules (Hardware Rev.2.1.0 and above)
- DIN-rail Dimensions and Instructions
- Wall-mounting Dimensions and Instructions (Optional: WK-112-01)
- Rack-mounting Dimensions and Instructions (Optional: RK-3U-02)
- Matters That Require Attention
- Connecting the Power Inputs
- Power Terminal Blocks
- PoE Power Terminal Blocks
- Wiring the Relay Contact
- Digital Input/Output
- Installing and Removing the Ethernet Modules
- Installing and Removing the Power Modules
- Grounding the Moxa Industrial DIN-rail Switch
- RS-232 with RJ45 Interface Console Connection
- USB Connection
- Reset to Factory Default Settings
- LED Indicators
- Specifications
- Supported SFP Modules
- Restricted Access Locations
- Special Conditions of Use
- Hazardous Location Usage Terms
- 18 -
Power
Consumption
(without
modules
consumption)
When using PWR-HV-P48:
110 VDC: 12.43 W
220 VDC: 12.87 W
110 VAC: 13.42 W
220 VAC: 14.08 W
When using PWR-LV-P48:
24 VDC: 12.67 W
48 VDC: 13.2 W
Power
Consumption of
module
LM-7000H-4GTX: 3.63 W
LM-7000H-4GPoE: 3.8 W
LM-7000H-4GSFP: 4.8 W
LM-7000H-4TX: 1.85 W
LM-7000H-4PoE: 1.85 W
Input Current
(without
modules
consumption)
When using PWR-HV-P48/PWR-HV-NP:
110 VDC: 0.11 A
220 VDC: 0.06 A
110 VAC: 0.29 A
220 VAC: 0.18 A
When using PWR-LV-P48/PWR-LV-NP:
24 VDC: 0.53 A
48 VDC: 0.28 A
Peak Inrush
Current
PWR-HV-P48/PWR-HV-NP:
110 VAC: < 10 A (t > 0.1 ms)
220 VAC: < 20 A (t > 0.1 ms)
PWR-LV-P48/PWR-LV-NP:
24 VDC: < 5 A (t > 0.1 ms)
48 VDC: < 10 A (t > 0.1 ms)
Maximum PoE
Power Output
per Port
36 W
15.4 W certified for Hazardous Location use
Total PoE Power
Budget
Max. 360 W (with one power supply) for total PD
consumption at 48 VDC input for PoE systems
Max. 360 W (with one power supply) for total PD
consumption at 53-57 VDC input for PoE+ systems
Max. 720 W (with two power supplies) for total PD
consumption at 48 VDC input for PoE systems
Max. 720 W (two powers) for total PD consumption at
53-57 VDC input for PoE+ systems
Overload Current
Protection
Present
Reverse Polarity
Protection
Present
Physical Characteristics
Ingress
Protection Rating
IP40
(This rating will only be achieved when the relay
output terminal block and all modules are installed.)
Dimensions
MDS-G4012/MDS-G4012-L3 Series:
134 x 115 x 163.25 mm
MDS-G4020/ MDS-G4020-L3 Series:
176 x 115 x 163.25 mm
MDS-G4028/MDS-G4028-L3 Series:
218 x 115 x 163.25 mm