Installation Guide
Table Of Contents
- MDS-G4000/MDS-G4000-L3 Series Quick Installation Guide
- Package Checklist
- Default Settings
- Panel Layouts
- Dimensions
- Ethernet Modules (Hardware Rev.2.0.0 and above)
- Power Modules (Hardware Rev.2.1.0 and above)
- DIN-rail Dimensions and Instructions
- Wall-mounting Dimensions and Instructions (Optional: WK-112-01)
- Rack-mounting Dimensions and Instructions (Optional: RK-3U-02)
- Matters That Require Attention
- Connecting the Power Inputs
- Power Terminal Blocks
- PoE Power Terminal Blocks
- Wiring the Relay Contact
- Digital Input/Output
- Installing and Removing the Ethernet Modules
- Installing and Removing the Power Modules
- Grounding the Moxa Industrial DIN-rail Switch
- RS-232 with RJ45 Interface Console Connection
- USB Connection
- Reset to Factory Default Settings
- LED Indicators
- Specifications
- Supported SFP Modules
- Restricted Access Locations
- Special Conditions of Use
- Hazardous Location Usage Terms
- 17 -
PWR-HV-P48/PWR-LV-P48
LED
Color
State
Description
EPS (External
Power Supply)
Amber
On
External power is being supplied to
the module's EPS input.
Off
No external power supply for PoE.
PWR Amber
On
Power is being supplied to the
module's power input.
Off
Power is not being supplied to the
module's power input.
PWR-HV-NP/PWR-LV-NP
LED
Color
State
Description
PWR Amber
On
Power is being supplied to the
module's power input.
Off
Power is not being supplied to the
module's power input.
Specifications
Interface
Gigabit Ethernet
4-ports 10/100/1000BaseT(X)
Console Port
RS-232 console with an RJ45 interface
LED Indicators PWR, EPS, STATE, SYNC, FAULT, MSTR/HEAD,
CPLR/TAIL
Relay Output
2 A @ 30 VDC (for Hazardous Location certified
models, the current carrying capacity is 1 A @ 30
VDC.)
Power Requirements
Input Voltage PWR-HV-P48:
110/220 VDC, 110 VAC, 60 Hz, 220 VAC, 50 Hz,
PoE: 48 VDC
PWR-LV-P48 (certified for Hazardous Location
use):
24/48 VDC
PoE: 48 VDC
PWR-HV-NP:
110/220 VDC, 110 VAC, 60 Hz, 220 VAC, 50 Hz
PWR-LV-NP: 24/48 VDC
Operating
Voltage
PWR-HV-P48:
88 to 300 VDC, 90 to 264 VAC, 47 to 63 Hz, PoE: 46
to 57 VDC
PWR-LV-P48: 18 to 72 VDC (24 to 48 VDC for
Hazardous Location), PoE: 46 to 57 VDC (48 VDC for
Hazardous Location)
PWR-HV-NP:
88 to 300 VDC, 90 to 264 VAC, 47 to 63 Hz
PWR-LV-NP:18 to 72 VDC