Installation Guide
Table Of Contents
- MDS-G4000-4XGS/ MDS-G4000-L3-4XGS Series Quick Installation Guide
- Package Checklist
- Default Settings
- Panel Layouts
- Dimensions
- Ethernet Modules (Hardware Rev.2.0.0 and above)
- Power Modules (Hardware Rev.2.1.0 and above)
- DIN-rail Dimension and Instructions
- Wall Mount Dimension and Instructions (Optional: WK-112-01)
- Rack-mounting Kit Dimensions and Instructions (Optional: RK-3U-02)
- Matters That Require Attention
- Connecting the Power Inputs
- Power Terminal Blocks
- PoE Power Terminal Blocks
- Wiring the Relay Contact
- Digital Input/Output
- Installing and Removing the Ethernet Modules
- Installing and Removing the Power Modules
- Grounding the Moxa Industrial DIN-rail Switch
- RS-232 with RJ45 Interface Console Connection
- USB Storage Connection
- Resetting to Factory Default Settings
- LED Indicators
- Specifications
- Restricted Access Locations
- 18 -
Weight
MDS-G4012-4XGS-T/MDS-G4012-L3-4XGS-T Series:
3.03 kg (6.68 lb)
MDS-G4020-4XGS-T/MDS-G4020-L3-4XGS-T Series:
3.40 kg (7.50 lb)
MDS-G4028-4XGS-T/MDS-G4028-L3-4XGS-T Series:
3.79 kg (8.36 lb)
LM-7000H-4GSFP: 0.30 kg (0.66 lb)
LM-7000H-4GTX: 0.24 kg (0.53 lb)
LM-7000H-4GPoE: 0.31 kg (0.69 lb)
LM-7000H-4TX: 0.24 kg (0.53 lb)
LM-7000H-4PoE: 0.31 kg (0.69 lb)
PWR-HV-P48-A: 0.42 kg (0.93 lb)
PWR-LV-P48-A: 0.40 kg (0.88 lb)
PWR-HV-NP/PWR-LV-NP: 0.34 kg (0.75 lb)
Installation
DIN-rail mount: Pre-installed by default
Wall mount: WK-112-01 (with optional kit)
19-inch rack mount: RK-3U-02 (with optional kit)
Environmental Limits
Operating Temp.
-40 to 75°C (-40 to 167°F)
Storage Temp.
-40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
5 to 95% (non-condensing)
Standards and Certifications
Safety EN 61010-2-201, UL 61010-2-201/62368-1,
IEC 62368-1/60950-1
EMC
EN 55032/35, EN 61000-6-2, EN 61000-6-4
EMI
CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 10V
IEC 61000-4-8 PFMF
IEC 61000-4-11 Voltage Dips & Interruptions
Rail Traffic
EN 50121-4
Traffic Control
NEMA TS2
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-31
Vibration
IEC 60068-2-6
Power Substation
IEC 61850-3, IEEE 1613
Warranty
Warranty Period
5 years
Details
See www.moxa.com/warranty
Restricted Access Locations
•
This equipment is intended to be used in Restricted
Access Locations, such as a computer room, with
access limited to service personnel or users who have
been instructed on how to handle the metal chassis of
equipment that is very hot. The location should only be accessible
with a key or through a security system.
• External metal parts of this equipment are extremely hot. Before
touching the equipment, you must take special precautions to
protect your hands and body from serious injury.