Installation Guide
Table Of Contents
- MDS-G4000-4XGS/ MDS-G4000-L3-4XGS Series Quick Installation Guide
- Package Checklist
- Default Settings
- Panel Layouts
- Dimensions
- Ethernet Modules (Hardware Rev.2.0.0 and above)
- Power Modules (Hardware Rev.2.1.0 and above)
- DIN-rail Dimension and Instructions
- Wall Mount Dimension and Instructions (Optional: WK-112-01)
- Rack-mounting Kit Dimensions and Instructions (Optional: RK-3U-02)
- Matters That Require Attention
- Connecting the Power Inputs
- Power Terminal Blocks
- PoE Power Terminal Blocks
- Wiring the Relay Contact
- Digital Input/Output
- Installing and Removing the Ethernet Modules
- Installing and Removing the Power Modules
- Grounding the Moxa Industrial DIN-rail Switch
- RS-232 with RJ45 Interface Console Connection
- USB Storage Connection
- Resetting to Factory Default Settings
- LED Indicators
- Specifications
- Restricted Access Locations
- 15 -
LM-7000H-4GPoE/LM-7000H-4PoE
LED
Color
State
Description
MS
(Module State)
Green
On
Normal operation.
Blinking
The module is booting up.
Off
This module is out of service.
Red On
1. The module failed to initialize.
2. A user inserted a module designed
for a different model.
3. When performing a cold start, the
module was removed and inserted
before initialization was complete.
EPS
(External Power
Supply for PoE
module)
Amber
On
Normal operation.
Off No external power supply for PoE.
Copper
(10/100
Mbps)
Green
On
When the port is active and links on
at 100 Mbps.
Blinking
When the port’s data is being
transmitted at 100 Mbps.
Off
When the port is inactive or link
down.
Amber
On
When the port is active and links on
at 10 Mbps.
Blinking
When the port’s data is being
transmitted at 10 Mbps.
Off
When the port is inactive or link
down.
Copper
(10/100/
1000Mbps)
Green
On
When the port is active and links on
at 1,000 Mbps.
Blinking
When the port’s data is being
transmitted at 1,000 Mbps.
Off
When the port is inactive or link
down.
Amber
On
When the port is active and links on
at 10/100Mbps.
Blinking
When the port’s data is being
transmitted at 10/100 Mbps.
Off
When the port is inactive or link
down.
PoE/PoE+
Green
On
When the port is connected to an
IEEE 802.3at powered device (PD).
Off
1. When power is not being supplied
to a powered device (PD), or
2. The port is not connected to an
IEEE 802.3at standard PD.
Amber
On
When the port is connected to an
IEEE 802.3af powered device (PD).
Blinking
The PoE power has been shut off
because of low power budget.
Red
On
Powered device (PD) detection
failure.
Blinking
Over current or short circuit on the
powered Device (PD) was detected.