ioLogik E1200 Series Quick Installation Guide Ethernet Remote I/O Edition 6.0, December 2016 Technical Support Contact Information www.moxa.
Package Checklist • • 1 ioLogik E1200 series remote I/O product Quick installation guide (printed) Specifications System Ethernet Protection Protocols Power Input Wiring Dimensions Weight Operating Temperature 2 x 10/100 Mbps switch ports, RJ45 1.5 KV magnetic isolation Modbus/TCP, TCP/IP, UDP, DHCP, Bootp, HTTP 24 VDC nominal, 12 to 36 VDC I/O cable max. 14 AWG 27.8 x 124 x 84 mm (1.09 x 4.88 x 3.31 in) under 200 g Standard Models: -10 to 60°C (14 to 140°F) Wide Temp.
Voltage Pulse Wave Width/Frequency Over-voltage Protection Over-current Limit Over-temperature Shutdown Output Current Rating Relay Output Type Contact Rating Inductance Load Resistance Load Breakdown Voltage Relay On/Off Time Initial Insulation Resistance Expected Life Initial Contact Resistance Pulse Output Analog Input Type Resolution I/O Mode Input Range Accuracy Sampling Rate (all channels) Input Impedance Built-in Resistor for Current Input Analog Output Resolution Output Range Voltage Output Accura
Thermocouple Input Sensor Type Millivolt Type Fault and Overvoltage protection Sampling Rate Resolution Accuracy Input Impedance J, K, T, E, R, S, B, N ±78.126 mV, ±39.062 mV, ±19.532 mV ±35 VDC (power off); +30 VDC, -25 VDC (power on) 12 samples/sec (all channels) 16 bits ±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C 10M ohms Installation Jumper Settings Models with DIO, AI, or external power channels require configuring the jumpers inside the enclosure.
I/O Wiring Digital Inputs/Outputs Analog Inputs/Outputs Relay Output (Form A) RTD Inputs -5-
TC Inputs NOTE A “load” in a circuit schematic is a component or portion of the circuit that consumes electric power. For the diagrams shown in this document, “load” refers to the devices or systems connected to the remote I/O unit. Mounting There are two sliders on the back of the unit for DIN rail and wall mounting. 1. 2. Mounting on a DIN rail: Pull out the bottom slider; latch the unit onto the DIN-rail, and push the slider back in.
LED Indicators Type Power Ready Color Amber Off Green Flashing Flashing Flashing Port 1 Port 2 EXT (E1213 only) Off Green Flashing Green Flashing Green Off Description System power is ON System power is OFF System is ready Flashes every 1 sec when the “Locate” function is triggered Flashes every 0.5 sec when the firmware is being upgraded An on/off period cycle: 0.5 second shows “Safe Mode” System is not ready.
How to Download the Software Step 1: Click on the following link to open the Support & Downloads search tool: http://www.moxa.com/support/support_home.aspx?isSearchShow=1 Step 2: Type the model name in the search box or select a product from the drop down box and then click Search. Step 3: Click the Software Packages link to download the latest software for the product. ATEX Information 1. 2. 3. 4. 5.