Datasheet

www.moxa.com
7
Environmental Limits
Operating Temperature Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Altitude 4000 m
5
Standards and Certifications
EMC EN 55032/24, EN 61000-6-2/-6-4
EMI CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
Hazardous Locations ATEX, Class I Division 2
6
Safety UL 508
Shock IEC 60068-2-27
Freefall IEC 60068-2-32
Vibration IEC 60068-2-6
Declaration
Green Product RoHS, CRoHS, WEEE
MTBF
Time ioLogik E1210 Series: 671,345 hrs
ioLogik E1211 Series: 923,027 hrs
ioLogik E1212 Series: 561,930 hrs
ioLogik E1213 Series: 715,256 hrs
ioLogik E1214 Series: 808,744 hrs
ioLogik E1240 Series: 474,053 hrs
ioLogik E1241 Series: 888,656 hrs
ioLogik E1242 Series: 502,210 hrs
ioLogik E1260 Series: 660,260 hrs
ioLogik E1262 Series: 631,418 hrs
Standards Telcordia SR332
Warranty
Warranty Period ioLogik E1214: 2 years
7
ioLogik E1210/E1211/E1212/E1213/E1240/E1241/E1242/E1260/E1262: 5 years
Details See www.moxa.com/warranty
5. Please contact Moxa if you require products guaranteed to function properly at higher altitudes.
6. ATEX and Class I Division 2 currently do not apply to the ioLogik E1213/E1213-T models.
7. Because of the limited lifetime of power relays, products that use this component are covered by a 2-year warranty.