Installation guide

- 6 -
STEP 2:
Mounting Moxa Industrial Media Converter on the wall
requires 4 screws. Use the IMC, with wall mount plates
attached, as a guide to mark the correct locations of the 4
screws. The heads of the screws should be less than 6.0
mm in diameter, and the shafts should be less than 3.5
mm in diameter, as shown in the figure at the right.
NOTE
Test the screw head and shank size by inserting
the screw into one of the keyhole shaped
apertures of the Wall Mounting Plates, before it
is screwed into the wall.
Do not screw the screws in all the way—leave a space of
about 2 mm to allow room for sliding the wall mount
panel between the wall and the screws.
6.0 mm
3.5 mm
STEP 3:
Once the screws are fixed in the wall, insert the four screw heads through the
large parts of the keyhole-shaped apertures, and then slide Moxa Industrial
Media Converter downwards, as indicated below. Tighten the four screws for
added stability.
II 3G
ATEX Information
1. Certification number DEMKO 09 ATEX0812123x
2. Ambient range (-40°C Tamb 75°C)
3. Certification string (Ex nC nL IIC T4)
4. Standards covered ( EN60079-0:2006, EN60079-15:2005)
5. The conditions of safe usage:
The Ethernet Communication Devices are to be mounted in an IP54
enclosure and used in an area of not more than pollution degree 2 as
defined by IEC60664-1. A 4mm2 conductor must be used when a
connection to the external grounding screw is used. Conductors
suitable for use in an ambient temperature of 93°C must be used for the
Power Supply Terminal.
Provisions shall be made, either in external to the apparatus, to prevent
the rated voltage being exceeded by the transient disturbances of more
than 40%.