Specifications
Technology
Standards IEEE802.3, 802.3u, Link Fault Pass-Through
Interface
RJ45 ports 10/100BaseT(X)
Fiber ports 100BaseFX (SC, ST connectors available)
LED Indicators Power, Fault, 10/100M, Full Duplex/Collision,
Dip Switch
Port break alarm mask, 100BaseFx Full/Half
duplex selection
Alarm Contact
One relay output with current carrying capacity of
1A @ 24 VDC
Optical Fiber
Multi
mode
Single
mode, 15
Single
mode, 40
Single
mode, 80
Distance, km
5 15 40 80
Wavelength, nm
1310 1310 1310 1550
Min. TX Output, dBm
-20 -15 -5 -5
Max. TX Output, dBm
-14 -6 0 0
Sensitivity, dBm
-34 to -30 -36 to -32 -36 to -32 -36 to -32
Recommended Diameter
62.5/125 9/125 9/125 9/125
(Core/Cladding) μm (1 dB/km,
800 MHz km)
Power
Input Voltage 24 VDC (12 to 48 VDC); Redundant inputs
Input Current (@24V) 0.16 A
Connection Removable Terminal Block
Overload Current Protection1.1 A
Reverse Polarity Protection Present
Mechanical
Casing IP30 protection, aluminum case
Dimensions (W x H x D) 53.6 x 135 x 105 mm
Weight 0.63 kg
Installation DIN-Rail, Wall Mounting
Environmental
Operating Temperature 0 to 60 (32 to 140℃
o
F),
-40 to 75
o
C (-40 to 167
o
F) for – T models
Storage Temperature -40 to 85 (℃ -40 to 185
o
F)
Ambient Relative Humidity 5 to 90% (non-condensing)
Regulatory Approvals
Safety
UL60950, UL 508, CSA C22.2 No. 60950,
EN60950
Hazardous Location UL/cUL Class I, Division 2, Groups A, B, C and D
ATEX Class I, Zone 2, EEx nC IIC
EMI FCC Part 15, CISPR (EN55022) class A
EMS EN61000-4-2 (ESD), level 3