User`s manual
IKS-6726 Featured Functions
3-10
Operation IEEE 1588/PTP
Setting Description Factory Default
Operation Disable or enable IEEE 1588 (PTP) operation Disable
Time Server Query Period
Setting Description Factory Default
Clock Mode Support software-based IEEE 1588 (PTP) mode Disable
Sync Interval Interval for sending synchronization message (in seconds) Disable
Sub-domain Name Support _DFLT (Default) domain only _DFLT
Setting Description Factory Default
Offset To Master (nsec) Deviation between local time and the reference clock (in
nanoseconds).
Grandmaster UUID When the clock has a port in PTP_SLAVE state, this member’s
value is the value of the grand master Clock’s Uuid field of the
last Sync message received from the parent of the slave port.
Parent UUID When the clock has a port in PTP_SLAVE state, this member’s
value is the value of the source-Uuid field of the last Sync
message received from the parent of the slave port.
Clock Stratum The stratum number describes one measure of the quality of a
clock. Each clock is characterized by a stratum number used by
the best master clock algorithm as one parameter of clock
quality.
4
Clock Identifier Properties of the clock DFLT
PTP Port Settings
Setting Description Factory Default
Port Enable Enable or disable PTP port operation None
Port Status Display PTP port real status PTP_DISABLED
System File Update—By Remote TFTP
The IKS-6726 supports saving your configuration or log file to a remote TFTP server or local host. Other
IKS-6726 switches can also load the configuration at a later time. The IKS-6726 also supports loading firmware
or configuration files from the TFTP server or a local host.