Installation Guide
Table Of Contents
- 13 - 
Fiber Communication 
Connector Type 
ST (single-mode and multi-mode), 100Base-FX 
Cable Requirements 
9/125 μm (single-mode) or 62.5/125 μm (multi-
mode) 
Wavelength  1310 nm (single-mode and mult i-mode) 
Tx Power 
> -5 dBm (single-mode) or > -20 dBm (multi-
mode) 
Rx Range 
-3 to -34 dBm (single-mode), -3 to -32 dBm 
(multi-mode) 
Environmental Limits 
Operating 
Temperature 
0 to 60°C (32 to 140°F) 
-40 to 75°C (-40 to 167°F) for -T model 
Storage Temperature 
-40 to 85°C (-40 to 185°F) 
Ambient Relative 
Humidity 
5 to 95% (non-condensing) 
Power 
Input Power Voltage 
12 to 48 VDC dual power input for redundancy 
Relay Output 
1 digital output relay to alarm (normal: closed) 
with current-carrying capacity of 1 A @ 30 VDC 
Mechanical Specifications 
Dimensions 
30.3 × 70 × 115 mm (1.19 × 2.76 × 4.53 in) 
Material 
Metal 
Gross Weight 
294 g (0.65 lb) 
사용자안내문  (User Guide) 
이  기기는  업무용  환경에서  사용할  목적으로  적합성평가를  받은 
기기로서가정용  환경에서  사용하는  경우  전파간섭의  우려가  있습니다. 
(This equipment has KC approval for use in industrial environments and 
could possibly interfere with household equipment.) 
기  종별 
Type of Equipment 
사용자안내문 
User Guide 
A  급    기기 (업무용    방송  통신기 
자재) 
Class A Equipment 
(Broadcasting and 
Communication Equipment for 
Industrial and Commercial Use) 
이    기기는    업무용  (A  급) 전자파  적합 
기기로서  판매자    또는    사용자는 이   
점을 주의하시기  바라며    가정  외의   
지역에서    사용하는    것을  목적으로 
합니다. 
This equipment is the EMC conformity 
equipment (Class A) for I
ndustrial and 
Commercial Use. The seller or user 
should take note of this as this 
equipment can be used in places that 
exclude homes. 