Installation guide
4
mode, and auto MDI/MDI-X connection
Fiber Ports 100BaseFX (SC type, multi-mode, and
single-mode)
LED Indicators Power, Fault, FX, 10/100, PoE
DIP Switch Port break alarm mask
Alarm Contact One relay output with current carrying capacity of
0.5A @ 48 VDC
Power
Input Voltage 48 VDC, redundant dual inputs
Input Current 1.6 A (@ 48 VDC)
Connection Removable “6-pin” Terminal Block
Overload Current
Protection
2.5 A (@ 48 VDC)
Reverse Polarity
Protection
Present
PoE (per port)
Minimum output voltage 44 VDC
Maximum output current 350 mA (@ 48V, normal powering mode)
Inrush current 400 to 450 mA (startup mode)
Overload detection 400 mA (max.)
Output current in short
circuit condition
400 to 450 mA
Overload and short
circuit time limit
50 to 75 ms
Turn off time 500 ms
Turn off voltage 2.8V
Maximum Output Power 15.4W
Mechanical
Casing IP30 protection, metal case
Dimensions 53.6 × 135 × 105 mm (W × H × D)
Weight 0.84 kg
Installation DIN-Rail, Wall Mounting
Environmental
Operating Temperature 0 to 60°C (32 to 140°F)
-40 to 75°C (-40 to 167°F) for -T models
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
5 to 95% (non-condensing)
Regulatory Approvals
Safety UL 508 (Pending)
Hazardous Location UL/cUL Class I, Division 2, Groups A, B, C and D
(Pending)
ATEX Class I, Zone 2, EEx nC IIC (Pending)
EMI FCC Part 15, CISPR (EN55022) class A
EMS EN61000-4-2 (ESD), Level 3
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 3
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3
EN61000-4-8