STEP 1: Insert the negative
(ground)/positive DI wires into the
┴
/I terminals, respectively.
STEP 2:
To keep the DI wires from
pulling loose, use a small flat
-blade
screwdriver to tighten the wire
-clamp
button
on the front of the terminal
block connector.
STEP 3:
Insert the plastic terminal
block connector prongs into the
terminal block receptor, which is
located on the EDS devices’ right side.
Rotating the Power Module
The power module for the EDS device can be rotated to make it easier
to fit your field site application.
Step 1:
Remove
the two screws that fasten the power module to the
EDS device
and remove the module.
Step 2:
Turn the power module clockwise so that the power, digital
input
, and relay output connectors can be moved upwards.
Step 3:
Replace the module back
on to the EDS device.
Step 4:
Fasten two screws on
to the module.
Communication Connections
Each EDS-G4014 Series switch has various types of communication
ports:
• RJ45 console port (RS-232 interface)
• USB storage port (type A connector, currently disabled)
• 10/100/1000BaseT(X) Ethernet ports
• 1000/2500BaseSFP slots
• microSD card slot (currently disabled)
Console Port Connection
The EDS device has one RJ45 console port (RS-232), located on the
front panel. Use either an RJ45-to-DB9 (see the cable following wiring
diagrams) to connect the EDS’s console port to your PC’s COM port.
You may then use a console terminal program, such as Moxa PComm
Terminal Emulator, to access the EDS that has a baud rate of 115200.