Installation Guide

- 15 -
LED Indicators
STATE (S), FAULT (F), PWR1 (P1), PWR2 (P2),
MSTR/HEAD (M/H), CPLR/TAIL (C/T), SYNC
Alarm Contact
1 normally open electromagnetic relay output with
current carrying capacity of 1 A @ 24 VDC
Digital Input 1 isolated digital input:
+13 to +30V for state “1”
-30 to +3V for state “0”
Max. input current: 8 mA
Power
Pre-installed Power
Module
-LV/-LV-T models: PWR-100-LV
-HV/-HV-T models: PWR-105-HV-I
Note
The EDS-G4014 Series supports modular power
supplies. The model names and power parameters
are determined by the installed power module.
For example:
EDS-G4014-T + PWR-100-LV = EDS-G4014-LV-T
EDS-G4014-T + PWR-105-HV-I = EDS-G4014-HV-
T
If you install a different power module, refer to the
specifications of the corresponding model. For
example, if you replace the power module of the
EDS-G4014-LV-T with the PWR-105-HV-I, refer to
the specifications of the EDS-G4014-HV-T.
Rated Voltage
-LV/-LV-T models: 12/24/48 VDC, redundant dual
inputs
-HV/-HV-T models: 110/220 VDC/VAC, single input
Operating Voltage
-LV/-LV-T models: 9.6 to 60 VDC
-HV/-HV-T models: 88 to 300 VDC, 85 to 264 VAC
Rated Current
-LV/-LV-T models: 12-48 VDC, 1.50-0.40 A or 24
VDC, 0.70 A
-HV/-HV-T models:110-220 VAC, 50-60 Hz, 0.30-
0.20 A or 110-220 VDC, 0.30-0.20 A
Power
Consumption
EDS-G4014-6QGS-LV(-T) models: 14.91 W
EDS-G4014-6QGS-HV(-T) models: 17.32 W
Inrush Current Max. 0.58 A @ 48 VDC (0.1 1 ms) (Applied to
-LV models)
Overload Current
Protection at Input
Present
Reverse Polarity
Protection
Present
Connection
2 removable 4-contact terminal blocks
Physical Characteristics
Housing
Metal, IP40 protection
Dimension
55 x 140 x 122.5 mm (2.17 x 5.51 x 4.82 in)
Weight
846 g (1.87 lb)
Installation
DIN-rail mounting, wall mounting (with optional
kit)
Environmental Limits
Operating
Temperature
-10 to 60°C (14 to 140°F) for standard models
-40 to 75°C (-40 to 167°F) for -T models
Storage
Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
5 to 95% (non-condensing)