Installation Guide
Table Of Contents
- EDS-G4014 Series Quick Installation Guide
- Package Checklist
- Default Settings
- Panel Views of EDS-G4014 Series
- Mounting Dimensions
- DIN-rail Mounting
- Wall Mounting (Optional)
- Wiring Requirements
- Grounding the Moxa EDS Series
- Suggested Wire Type for Wiring Relay Contact (RELAY), Digital Input (DI), and Power Inputs (P1/P2)
- Wiring the Relay Contact
- Wiring the Redundant Power Inputs
- Wiring the Digital Inputs
- Rotating the Power Module
- Communication Connections
- Reset Button
- Turbo Ring DIP Switch Settings
- LED Indicators
- Specifications
- 11 -
LC- Port Pinout s
LC- Port to LC- Por t Ca ble W irin g
ATTEN TI ON
This is a Class 1
Laser / LED product . To av oid causing ser ious
dam age to your eyes, do not st are direct ly into t he Laser Beam .
Rese t But t on
There are t wo funct ions available on t he Reset But t on. One is t o r eset
the Ethernet swit ch to fact or y default set tings by pressing and h olding
the Reset but t on for 5 seconds. Use a point ed obj ect , such as a
st raight ened paper clip or t oothpick , t o depress t he Reset but t on. This
will cause the STATE LED t o blink once a second. Aft er depressing th e
but ton for 5 cont inuous seconds, t he STATE LED will star t t o blink
rapidly. This indicat es that fact ory default set tings have been loaded
and you can r elease t he reset but t on. The ot her funct ion is t o reboot
t he device by depr essing t he r eset but t on for less t han five seconds.
Tur b o Ring DI P Sw it ch Set t in gs
The EDS devices are plug- and-play m anaged r edundant Ethernet
sw it ches. The propr iet ar y Turbo Ring prot ocol was developed by Moxa
to pr ovide bet t er network reliabilit y and fast er recovery t im e. Moxa
Turbo Ring’s recover y t im e is less t han 50 m s ( Turb o Ring V2 ) —
com pared t o a 3- t o 5- m inut e recovery t im e for com m er cial swit ches—
decr easing t he possible loss caused by n et work failur es in an indust r ial
set t ing.
Ther e ar e five Hardware DI P Switches for Turbo Rin g on t he bott om
panel of t he EDS device t hat can help setup t he Turbo Ring easily
within seconds. I f you do not want t o use a hardw are DI P swit ch t o
set up t he Turbo Ring, y ou can use a w eb browser , t elnet , or console t o
disable this funct ion.
N OTE
Please refer t o t he Tur bo Rin g
sect ion in User's Man ual for
m ore det ail informat ion about t he set ting and usage of
Tu rbo
Rin g V2 .