User`s manual

Communication Redundancy Turbo Ring
2-7
Explanation of “Settings” Items
Redundancy Protocol
Setting Description Factory Default
Turbo Ring Select this item to change to the Turbo Ring configuration page.
None
Turbo Ring V2 Select this item to change to the Turbo Ring V2 configuration page.
Turbo Chain Select this item to change to the Turbo Chain configuration page.
RSTP (IEEE 802.1W/
802.1D-2004)
Select this item to change to the RSTP configuration page.
None Ring redundancy is not active
Set as Master
Setting Description Factory Default
Enabled Select this switch as Master
Not checked
Disabled Do not select this switch as Master
Redundant Ports
Setting Description Factory Default
1st Port Select any port of the switch to be one of the redundant ports. See the following table
2nd Port Select any port of the switch to be one of the redundant ports. See the following table
Default 1st Port Default 2nd Port
EDS-400A Series
EDS-505A/508A/516A Series
The second from the last port The last port
EDS-518A Series Port G1 Port G2
EDS-510A Series Port G2 Port G3
EDS-608/616 The third port of the last module The fourth port of the last module
EDS-611/619 Port G2 Port G3
EDS-728/828 Series Port 1-1 Port 1-2
IKS-6726 Series without Gigabit Ethernet module:
Port 1-1
with Gigabit Ethernet module:
Port 4-1
without Gigabit Ethernet module:
Port 1-2
with Gigabit Ethernet module:
Port 4-2
IKS-G6524/G6824 Series
ICS-G7526/G7528/
G7826/G7828 Series
The second from the last port The last port
Enable Ring Coupling
Setting Description Factory Default
Enable Select this switch as Coupler
Not checked
Disable Do not select this switch as Coupler
Coupling Port
Setting Description Factory Default
Coupling Port Select any port of the switch to be the coupling port See the following table
Coupling Control Port
Setting Description Factory Default
Coupling Control Port Select any port of the EDS to be the coupling control port See the following table