Installation Guide
Table Of Contents
- EDS-4014 Series Quick Installation Guide
- Package Checklist
- Default Settings
- Panel Views of EDS-4014 Series
- Mounting Dimensions
- DIN-rail Mounting
- Wall Mounting (Optional)
- Wiring Requirements
- Grounding the Moxa EDS Series
- Suggested Wire Type for Wiring Relay Contact (RELAY), Digital Input (DI), and Power Inputs (P1/P2)
- Wiring the Relay Contact
- Wiring the Redundant Power Inputs
- Wiring the Digital Inputs
- Rotating the Power Module
- Communication Connections
- Reset Button
- Turbo Ring DIP Switch Settings
- LED Indicators
- Specifications
- 2 -
Pa cka ge Check list
The EDS- 4014 Ser ies indust rial DI N- rail EtherDevice Switch ( EDS) is
shipped wit h t he following item s. I f any of t hese it em s are m issing or
dam aged, please cont act your custom er service represent ative for
assist an ce.
• 1 EDS- 4014 Ether net swit ch
• Quick inst allat ion guide ( print ed)
• Warr ant y car d
• Subst ance disclosure t able
• Product cer tificate of quality inspect ion ( Sim plified Chinese)
• Product not ices ( Sim plified Chinese)
N OTE
You can find inform at ion and soft w ar e downloads on the
relevant produ ct pages lo
cat ed on Moxa’s w ebsit e:
www .m oxa.com
De fault Se t t ings
• I P address: 192.168.1 27.253
• Subnet Mask : 255.255.255.0
• Usern am e: adm in
• Passw or d: m oxa
Pa n el Vie w s of EDS- 4 0 1 4 Series
Fron t Pan el Vie w
1. 100/ 1000BaseT( X) LED
indicat or
2. 10BaseT( X) LED indicat or
3. 10/ 100BaseT( X) port s, por ts 1
t o 8
4. 100/ 1000BaseSFP port s, port s
G1 t o G4
5. 1000BaseT( X) LED indicat or
6. 1000/ 2500BaseSFP por ts, port s
QG1 and QG2
7. 1000/ 2500BaseSFP LED
indicator
8. Grounding connect or screw
9. Ter m inal blocks for po
wer in put,
digital in put , and relay
10.
LED indicator s: STATE (S),
FAULT ( F), PWR1 ( P1) , PWR2
( P2), MSTR/ HEAD ( M/ H),
CPLR/ TAI L ( C/ T) , SYNC
11.
Console por t ( RJ45, RS- 232)
12.
USB st orage port (t ype A,
cur rent ly disabled)
13. Model nam e