User Manual
- 13 - 
ST-Port Pinouts 
ST-Port to ST-Port Cable Wiring 
ATTENTION
This is a Class 1 Laser/LED product. 
To avoid causing serious 
damage to your eyes, do not stare directly into the Laser Beam. 
Redundant Power Inputs 
Both power inputs can be connected simultaneously to live DC power 
sources. If one power source fails, the other live source acts as a 
backup, and automatically supplies all of the EDS’s power needs. 
DIP Switch Settings 
EDS-205A/208A DIP Switches 
The default setting for each DIP Switch is 
O
FF. The 
following table explains the effect of 
setting the DIP Switches to the O
N positions. 
DIP Switch 
Setting 
Description 
---- 
– 
Serves no function (reserved for future use). 
BSP 
ON 
Enables broadcast storm protection 
OFF 
Disables broadcast storm protection 
ATTENTION
To actively updated DIP switch settings, power
 off and then 
power on the EDS. 
LED Indicators 
The front panel of the Moxa EtherDevice Switch contains several LED 
indicators. The function of each LED is described in the table below. 
LED 
Color 
State 
Description 
P1  AMBER
On 
Power is being supplied to power input P1. 
Off 
Power is not being supplied to power input 
P1. 
P2  AMBER
On 
Power is being supplied to power input P2. 
Off 
Power is not being supplied to power input 
P2. 
10M  GREEN
On 
TP port’s 10 Mbps link is active. 
Blinking 
Data is being transmitted at 10 Mbps. 
Off 
TP Port’s 10 Mbps link is inactive 
100M 
GREEN 
On 
TP/FX port’s 100 Mbps link is active. 