User Manual
- 18 - 
Specifications 
Technology 
Standards 
IEEE 802.3 for 10BaseT, 
IEEE 802.3u for 100BaseT(X) and 100Base FX, 
IEEE 802.1p for Class of Service 
Flow Control 
EEE 802.3x flow control, back pressure flow control 
Interface 
RJ45 Ports 
10/100BaseT(X) auto negotiation speed 
Fiber Ports 
100BaseFX ports (SC/ST connector) 
LED Indicators 
PWR1, PWR2, Fault, 10/100M, 100M 
DIP Switch 
Port break alarm, QoS, BSP 
Alarm Contact 
One relay output with current carrying capacity of  
1A @ 24 VDC 
Optical Fiber 
100Base FX 
Multi-mode 
Single-mode 
40 km 
Single-mode 
80 km 
Fiber Cable Type  OM1
50/125 
ยตm 
G.652  G.652 
800 
MHz*Km 
Typical Distance 
4 
km 
5 km  40 km  80 km 
Wavelength 
Typical 
(nm) 
1300  1310  1550 
TX Range 
(nm) 
1260 to 1360  1280 to 1340
1530 to 1570
RX Range 
(nm) 
1100 to 1600  1100 to 1600
1100 to 1600
Optical 
Power 
TX Range 
(dBm) 
-10 to -20  0 to -5  0 to -5 
RX Range 
(dBm) 
-3 to -32  -3 to -34  -3 to -34 
Link Budget 
(dB) 
12  29  29 
Dispersion 
Penalty 
(dB) 
3  1  1 
Note: When connecting 40 km or 80 km single-mode fiber over a short 
distance, we recommend putting an attenuator to prevent the 
transceiver from being damaged by excessive optical power. 
Typical Distance: To reach the typical distance of a specified fiber 
transceiver, please refer to the following formula: Link budget(dB) > 
dispersion penalty(dB) + total link loss(dB). 
Switch Properties 
MAC Table Size 
8 K 
Packet Buffer Size 
2 Mbits 
Processing Type 
Store and Forward 
Power 
Input Voltage 
12/24/48 VDC redundant dual inputs 