User Manual
- 19 -
Input Current
EDS-2016-ML: 0.296 A (max.)
EDS-2016-ML-MM-SC: 0.443 A (max.)
EDS-2016-ML-MM-ST: 0.458 A (max.)
EDS-2016-ML-SS-SC: 0.460 A (max.)
Relay output: 24 VDC, 1 A, Resistance
Connection Removable 6-contact terminal block 28-14 AWG,
1.7 lb-in
All wires must be able to withstand at least 85°C
Overload Current
Protection
Present
Reverse Polarity
Protection
Present
Mechanical
Casing
IP30 protection, metal case
Dimensions
(W x H x D)
EDS-2016-ML Copper model:
36 x 135 x 95 mm (1.41 x 5.31 x 3.74 in)
EDS-2016-ML Fiber model:
58 x 135 x 95 mm (2.28 x 5.31 x 3.74 in)
Weight EDS-2016-ML Copper model: 486 g (1.07 lb)
EDS-2016-ML Fiber model: 648 g (1.43 lb)
Installation
DIN-rail, Wall Mounting (optional kit)
Environmental Limits
Operating
Temperature
-10 to 60°C (32 to 140°F)
-40 to 75°C (-40 to 167°F) for -T models
Storage
Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
5 to 95% (non-condensing)
Altitude
Up to 2,000 m
Note This device must be installed within a suitable, final
enclosure
Regulatory Approvals
Note: Only for indoor use.
Safety
UL 61010-2-201, EN 62368-1(LVD)
EMI
FCC Part 15, CISPR (EN55032) class A
EMS EN61000-4-2 (ESD), Level 3
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 3
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3
EN61000-4-8
Hazardous
Location*
UL/cUL Class I, Division 2, Groups A, B, C, and D;
ATEX Zone 2, Ex nA nC IIC T4 Gc
Maritime*
DNV GL, ABS, LR, NK
Rail Traffic
EN 50121-4
Traffic Control*
NEMA TS2
Shock
IEC60068-2-27
Free Fall
IEC60068-2-32
Vibration
IEC60068-2-6
WARRANTY
5 years
Address of
Manufacturer
FL. 4, No.135, Lane 235, Baoqiao Road, Xindian
District, New Taipei City, Taiwan R.O.C.
* Certification process is underway.