User Manual
- 11 - 
ATTENTION
This product is intended to be mounted to a well
-grounded 
mounting surface, such as a metal panel. 
Wiring the Power Input 
The top two contacts and the bottom two contacts of the 2 or 3 contact 
terminal block connector on the EDS’s top panel are used for the EDS’s 
two DC inputs. Top and front views of one of the terminal block 
connectors are shown here. 
STEP 1:  
Insert the negative/positive DC wires into the V-/V+ terminals. 
STEP 2:  
To keep the DC wires from pulling loose, use a small flat-blade 
screwdriver to tighten the wire-clamp screws on the front of the 
terminal block connector. 
STEP 3:  
Insert the plastic terminal block connector prongs into the terminal 
block receptor, which is located on the EDS’s top panel. 
NOTE 
The power source comes from secondary circuits. These circuits 
are separated from mains circuits by a transformer in which the 
primary windings are separated from the secondary windings 
by reinforced installation, double installation, or a screen 
connected to the protective conductor terminal. 
ATTENTION
Before connecting 
the EDS to the DC power inputs, make sure 
the DC power source voltage is stable. 
ATTENTION
One individual conductor in a clamping point with 28
-14 AWG 
wire size, and a torque value of 1.7 lb-in should be used. 
Communication Connections 
The EDS-2008-EL/ELP models have 10/100BaseT(X) Ethernet ports and 
100BaseFX Ethernet ports. 