User`s manual

EDR-G903/G902 Features and Functions
3-65
DI transition (On -> Off)
Cold start
Factory default Warm start
System restart Warm start
Firmware Upgrade Warm start
Configuration Upgrade Warm start
NOTE The maximum number of event entries is 1000.
Using Syslog
This function provides the event logs for the syslog server. The function supports 3 configurable syslog servers
and syslog server UDP port numbers. When an event occurs, the event will be sent as a syslog UDP packet to
the specified syslog servers.
Syslog Server 1/2/3
Setting Description Factory Default
IP Address Enter the IP address of the Syslog Server used by your
network.
None
Port Destination
(1 to 65535)
Enter the UDP port of the Syslog Server. 514
Using HTTPs/SSL
To secure your HTTP access, the EtherDevice Router supports HTTPS/SSL to encrypt all HTTP traffic. Perform
the following steps to access the EtherDevice Routers web browser interface via HTTPS/SSL.
1. Open Internet Explorer and type https://< EtherDevice Router’s IP address> in the address field. Press
Enter to establish the connection.