Datasheet

www.moxa.com
2
Stop Bits 1, 1.5, 2
Parity None, Even, Odd, Space, Mark
Flow Control None, RTS/CTS, XON/XOFF
Isolation CP-134U-I Series: 2 kV
Serial Signals
RS-232 TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422 Tx+, Tx-, Rx+, Rx-, RTS+, RTS-, CTS+, CTS-, GND
RS-485-4w Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w Data+, Data-, GND
Serial Software Features
Windows Drivers DOS, Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64),
Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP
Embedded
Linux Drivers Linux kernel 2.4.x, Linux kernel 2.6.x, Linux kernel 3.x, Linux kernel 4.x, Linux kernel 5.x
UNIX Drivers QNX 6, SCO OpenServer, UnixWare 7, Solaris 10, FreeBSD
Power Parameters
Input Current CP-134U Series: 180 mA @ 5 VDC
CP-134U-I Series: 850 mA @ 5 VDC
Physical Characteristics
Dimensions CP-134U Series: 82.5 x 120 mm (3.24 x 4.72 in)
CP-134U-I Series: 115 x 120 mm (4.52 x 4.72 in)
LED Interface
LED Indicators Built-in Tx, Rx LEDs for each port
Environmental Limits
Operating Temperature Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Standards and Certifications
EMC EN 55032/24
EMI CISPR 32, FCC Part 15B Class B
EMS IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
Declaration
Green Product RoHS, CRoHS, WEEE
MTBF
Time 480,209 hrs
Standards Telcordia SR332