User`s manual

Software Installation
Intellio C320Turbo/PCI User's Manual 3-31
Baud Rate Mapping
This advanced feature is set to “High Band” by default, indicating that the baud
rate 50, B50, will no longer stand for 50 bps. Instead, B50 means 57600 bps, B75
is for 115.2 Kbps, B110 is for 230.4 Kbps, and B134 is for 460.8 Kbps. You may
press F1 Help for on-line details.
2. Press PageDown to enter the “Advanced Port Settings” sub-dialog, there are
some noticeable fields to initialize the ports for advanced usage. You may skip
this step if you do not concern these features.
Feature
In the “Port Feature Settings” sub-dialog, port feature [Terminal] is the only
choice if On Board Line Discipline is set to “Enable”. This is good for terminal
application.
However, if On-Board Line Discipline is set to “Disable”, port feature could be
either [Transparent] or [Terminal]. In case of [Terminal], all the tty line
discipline jobs will be done on host which surely is a burden to the host. In case
of [Transparent], no time-consuming tty line discipline is applied for the port