User`s manual

Software Installation
Intellio C320Turbo/PCI User's Manual 3-7
11. Once the system restarts, you may check the event log issued by MOXA drive to
see if the ports of the board are initialized successfully.
Enter the [Administrative] group, [Event Viewer] and select [Application
Event Log] to check a successful message similar to “MOXA
C320Turbo/PCI Multiport Board #1: addr(XXX) O.K.” for each configured board.
D If an error message similar to “MOXA C320Turbo/PCI Multiport Board #1
addr(XXX): IRQ(10) test failure!” appears, refer to the “Troubleshooting”
chapter for solutions.
Note ! Once the board and driver are installed and the system restarts
successfully, you can start to develop applications by using
PComm library (See “Serial Programming Tools” chapter) or
using Microsoft Win32 API. you can also execute any ready-
made application, such as PComm utility Terminal emulator
(See “Serial Programming Tools” chapter) or HyperTerminal
to transmit/receive data, as well as Remote Access Service to
provide dial-up networking capability.
Configuring Board and Port
If you already have installed the driver and want to re-configure the board and port,
add more boards or delete boards, please follow this procedure.
1. Open [Control Panel], click [Network] and select the [Adapters] tab.
2. Select “MOXA Intellio Family Adapter in the “Installed Adapter Cards:”.