User Manual
- 14 -
Specifications
Input Current
0.64 A @ 12 VDC; 0.16 A @ 48 VDC
Input Voltage
12 to 48 VDC, redundant dual DC
power inputs or 48 VDC
Power-over-
Ethernet (IEEE 802.3af
compliant)
Power Consumption
7.68 W
Operating Temperature -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
ATTENTION
The
AWK-4131A is NOT
a portable mobile device and should be
located 20
cm away from the human body.
The
AWK-4131A is NOT designed for the general public. A
well
-trained technician is required to deploy AWK-4131As and
safely establish a wireless network.
ATTENTION
This device complies with part 15 of the FCC Rules. Operation is
subject t
o the following two conditions:
1.
This device may not cause harmful interference, and
2.
This device m
ust accept any interference received, including
interference that may cause undesired operation.
ATTENTION
Do not locate the antenna near overhead power lines or other
electric light or power circuits, or where it can come into contact
with such circui
ts. When installing the antenna, take extreme
care not to come into contact with such circuits, because they
may cause serious injury or death. For proper installation and
grounding of the antenna
, refer to national and local codes (for
example, U.S.
: NFPA 70; National Electrical Code (NEC) Article
810; Canada: Canadian Electrical Code Section 54).
NOTE
For installation flexibility, either the antenna A or the antenna B
may be selected for use. Make sure the antenna connect
ion
matches the antenna configured in the
AWK-4131A web
interface.
To protect the connectors and RF module, all radio ports should
be terminated by either an antenna or a terminator. We strongly
recommend using resistive terminators for terminating the
unused antenna ports.