Datasheet

www.moxa.com
4
LED Interface
LED Indicators PWR, FAULT, STATE, WLAN, LAN
Input/Output Interface
Alarm Contact Channels Relay output with current carrying capacity of 1 A @ 24 VDC
Buttons Reset button
Digital Inputs +13 to +30 V for state 1
+3 to -30 V for state 0
Max. input current: 8 mA
Physical Characteristics
Housing Metal
IP Rating IP68
Dimensions 224 x 147.7 x 66.5 mm (8.82 x 5.82 x 2.62 in)
Weight 1,400 g (3.09 lb)
Installation Wall mounting (standard), DIN-rail mounting (optional), Pole mounting (optional)
Power Parameters
Input Current 0.64 A @ 12 VDC, 0.16 A @ 48 VDC
Input Voltage 12 to 48 VDC, Redundant dual inputs, 48 VDC Power-over-Ethernet
Power Connector M12 A-coded 5-pin male connector
Power Consumption 7.68 W (max.)
Reverse Polarity Protection Supported
Environmental Limits
Operating Temperature -40 to 75°C (-40 to 167°F)
Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Standards and Certifications
EMC EN 61000-6-2/-6-4
EMI CISPR 32, FCC Part 15B Class B
EMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
Radio EN 300 328, EN 301 489-1/17, EN 301 893, FCC ID SLE-WAPN008, ANATEL, MIC, NCC,
RCM, SRRC, WPC, KC
Safety EN 60950-1, UL 60950-1
Vibration IEC 60068-2-6
MTBF
Time 440,764 hrs
Standards Telcordia SR332