Installation Guide

- 5 -
To remove the AWK-3251A-M12-RCC from the DIN rail, do the
following:
STEP 1:
Pull down the latch on the DIN
-
rail kit with a screwdriver.
STEP 2 & 3:
Slightly pull the
AWK-3251A-
M12
-RCC forward and lift it up
to remove it from the mounting
rail.
Wall Mounting (Optional)
For some applications, it may be more convenient to mount the AWK-
3251A-M12-RCC to a wall, as illustrated below.
STEP 1:
Remove the aluminum DIN-rail attachment plate from the AWK-3251A-
M12-RCC, and then attach the wall-mounting plates with M3 screws, as
shown in the following diagrams.
STEP 2:
Mounting the
AWK-3251A-M12-RCC to a wall requires 2
screws. Use
the AWK-3251A-M12-RCC device, with
wall
-mounting plates attached, as a guide to mark the
correct locations of the
2 screws on the wall
. The heads
of the screws should be less than 6.0 mm in diameter,
the
shafts should be less than 3.5 mm in diameter,
and
the
screw length should be at least 15 mm, as sho
wn in
the figure on the right.
Do not drive the screws in all the wayleave a space of about 2 mm to
allow room for sliding the wall-mounting panel between the wall and
the screws.
NOTE
Test the screw head and shank size by inserting the screws
into
one of the keyhole shaped apertures of the wall
-mounting
plates before they are fixed to the wall.