Installation Guide
Table Of Contents
- 12 -
LED
Color
State
Description
Green On
System startup completed and is operating
normally.
LAN
Green
On
LAN port’s 1000 Mbps link is active.
Blinking
(3 Hz)
Data is being transmitted at 1000 Mbps.
Off
LAN port’s 1000 Mbps link is inactive.
Amber
On
LAN port’s 10/100 Mbps link is active.
Blinking
(3 Hz)
Data is being transmitted at 10/100 Mbps.
Off
LAN port’s 10/100 Mbps link is inactive.
2.4G
Green
On
The AWK is in Client-based mode (Client,
Client-Router, ACC-Slave).
Blinking
The AWK is in Client-based mode and is
transmitting traffic.
Amber
On
The AWK is in AP-based mode (AP, Master,
ACC-Master).
Blinking
Data is being transmitted over the 2.4 GHz
band.
Green/
Amber
Off
The WLAN is in Client/Slave/ACC
Master/ACC Slave mode without an
established connection, or the WLAN is not
working properly.
5G
Green
On
The AWK is in Client-based mode (Client,
Client-Router, ACC-Slave).
Blinking
The AWK is in Client-based mode and is
transmitting traffic.
Amber
On
The AWK is in AP-based mode (AP, Master,
ACC-Master).
Blinking
Data is being transmitted over the 2.4 GHz
band.
Green/
Amber
Off
The WLAN is in Client/Slave/ACC
Master/ACC Slave mode without an
established connection, or the WLAN is not
working properly.
Signal
Strength
(5 LEDs)
Green
On
Signal strength indicator (for
Client/Slave/ACC Slave/ACC Master only).
Off
The AWK is in AP/Master/Sniffer mode, or
no connection is established.
Specifications
Input Current
2.01 A @ 12 VDC, 0.5 A @ 48 VDC
Input Voltage 12 to 48 VDC, redundant dual power inputs,
48 VDC Power over Ethernet
Power Consumption
24.12 W (max.)
Relay Output
24 VDC, 1 A (resistive load)
Operating Temperature Standard Models: -25 to 60°C (-13 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to
167°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
NOTE
To meet the standard for IP30 protection, all unused ports
should be covered with the protective caps.