Installation Guide

- 10 -
Wiring the Relay Contact
The AWK-3251A-M12-RCC has one relay output, which consists of the
two contacts of the terminal block on the AWK-3251A-M12-RCC’s top
panel. Refer to the previous section for detailed instructions on how to
connect the wires to the terminal block connector, and how to attach
the terminal block connector to the terminal block receptor. These relay
contacts are used to indicate user-configured events. The two wires
attached to the Relay contacts form an open circuit when a user-
configured event is triggered. If a user-configured event does not
occur, the Relay circuit will be closed.
Wiring the Digital Inputs
The AWK-3251A-M12-RCC has two sets of digital inputsDI1 and DI2.
Each DI comprises two contacts of the 10-pin terminal block connector
on the AWK-3251A-M12-RCC’s top panel. Refer to the “Wiring the
Redundant Power Inputs” section for detailed instructions on how to
connect the wires to the terminal block connector, and how to attach
the terminal block connector to the terminal block receptor.
Cable Holder Installation
Attach the cable holder to the bottom of the AWK-3251A-M12-RCC to
keep cabling neat and avoid accidents that result from untidy cables.
STEP 1: Screw the cable holder onto the bottom
of the
AWK-3251A-M12-RCC.
STEP 2:
After mounting the AWK-3251A-M12-RCC and plugging in the
LAN cable, tighten the cable along the device and wall.