Datasheet
www.moxa.com
4
LED Interface
LED Indicators PWR1, PWR2, PoE, FAULT, STATE, SIGNAL, WLAN, LAN
Input/Output Interface
Digital Inputs 2
Max. input current: 8 mA
+13 to +30 V for state 1
+3 to -30 V for state 0
Alarm Contact Channels Relay output with current carrying capacity of 1 A @ 24 VDC
Buttons Reset button
Physical Characteristics
Housing Metal
IP Rating IP30
Dimensions 52.7 x 135 x 105 mm (2.08 x 5.32 x 4.13 in)
Weight 860 g (1.9 lb)
Installation DIN-rail mounting, Wall mounting (with optional kit)
Power Parameters
Input Current 0.6 A @ 12 VDC, 0.15 A @ 48 VDC
Input Voltage 12 to 48 VDC, Redundant dual inputs, 48 VDC Power-over-Ethernet
Power Connector 1 removable 10-contact terminal block(s)
Power Consumption 7.2 W (max.)
Reverse Polarity Protection Supported
Environmental Limits
Operating Temperature Standard Models: -25 to 60°C (-13 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Standards and Certifications
EMC EN 61000-6-2/-6-4
EMI CISPR 32, FCC Part 15B Class B
EMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
IEC 61000-4-6 CS: 3 V
IEC 61000-4-8 PFMF
Hazardous Locations ATEX, Class I Division 2, IECEx
Radio EN 300 328, EN 301 489-1/17, EN 301 893, FCC ID SLE-WAPN008, ANATEL, MIC, NCC,
RCM, SRRC, WPC, KC, RCM
Safety EN 60950-1, UL 60950-1
Vibration IEC 60068-2-6