You should also pay attention to the following items:
Use separate paths to route wiring for power and devices. If power
wiring and device wiring paths must cross, make sure the wires are
perpendicular at the intersection point.
NOTE
Do not run signal or communications wiring and power wiring in
the same wire conduit. To avoid interference, wires with
different signal characteristics should be routed separately.
You can use the type of signal transmitted through a wire to
determine which wires should be kept separate. The rule of thumb
is that wiring with similar electrical characteristics can be bundled
together.
Keep input wiring and output wiring separate.
It is strongly advised that you label wiring to all devices in the
system when necessary.
ATTENTION
This product is intended to be supplied by a UL
-listed power
adapter suitable for use at
a Thermom
echanical Analysis (TMA)
of
75 degree Celsius, which output meets SELV circuit and LPS
standards;
output rated 9 to 30 VDC, 1.3A min. or 24 VDC,
0.49A min.
ATTENTION
Make sure
the external power adapter (includes power cords
and plug assemblies)
provided with the unit is certified and
suitable for use in your country.
Grounding the Moxa AWK-1137C
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from
the ground screw to the grounding surface prior to connecting devices.
ATTENTION
This product is intended to be mounted to a well
-grounded
mounting surface, such as a metal panel.
There must be no
electrical potential difference between any two grounding
points
; otherwise, there is a risk that the device could be
destroyed.