User Manual

- 8 -
ATTENTION
Make sure
the external power adapto
r (includes power cords and
plug assemblies) provided
with the unit is certified and suitable
for use in your country.
Grounding the Moxa AWK-1131A
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from the
ground screw to the grounding surface prior to connecting devices.
ATTENTION
This product is intended to be mounted
on to a well-grounded
mounting surface, such as a metal panel. The potential difference
between any two grounding points must be zero. If the potential
difference is NOT zero, the product could be permanently
damaged.
Installations with Cable Extended Antennas for Outdoor
Applications
If the antenna or the AWK device is installed outdoors or in an open-air
setting, proper lightning protection is required to prevent direct lightning
strikes on the AWK device. In order to prevent coupling currents from
nearby lightning strikes, a lightning arrester should be installed as part of
your antenna system. Ground the device, antenna, as well as the arrester
properly to provide maximum outdoor protection for the device.
Arrester Accessories
SA-NMNF-01: Surge arrester, N-type (male) to N-type (female)
SA-NFNF-01: Surge arrester, N-type (female) to N-type (female)