Specifications
Input Current
0.56 A @ 12 VDC, 0.14 A @ 48 VDC
Input Voltage 12 to 48 VDC, redundant dual DC power
inputs
Power Consumption
6.96 W
Operating Temperature
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to
167°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
ATTENTION
The AWK
-1131A is NOT
a portable mobile device and should be
located at least 20 cm
away from the human body.
The AWK
-1131A is NOT designed for the general public. A
well
-trained technician is required to deploy the AWK-1131A
units and safely establish a wireless network.
ATTENTION
This device complies with Part 15 of the FCC rules.
Operation is
subject to the following conditions:
1.
This device may not cause harmful interference.
2.
This device must accept any interference received,
including
interference that may cause undesired operation.
ATTENTION
Do not locate
the antenna near overhead power lines or other
electric light or power circuits, or where it can come into contact
with such circuits. When installing the antenna
, take extreme
care not to come into contact with such circuits, because they
may cause seriou
s injury or death. For proper installation and
grounding of the antenna
,
refer to national and local codes (for
example, U.S.
: NFPA 70; National Electrical Code, Article 810;
Canada: Canadian Electrical Code, Section 54).
NOTE
For installation flexibility, either the A antenna (on the front
panel) or the B antenna (on the top panel) may be selected for
using. Make sure the antenna connection matches the antenna
configured in the AWK
-1131A web interface.
To protect the connectors and RF module, all radio ports should
be terminated by either an antenna or a terminator. We strongly
recommend using resistive terminators for terminating the
unused antenna ports.