User`s manual

AWK-1121/1127 Web Console Configuration
3-38
Port Alias
Setting Description Factory Default
free text (e.g.,
“Secondary console
connection”)
This is an optional free text field to help you differentiate one
serial port from another. It does not affect operation of the
AWK-1127.
Baud Rate
Setting Description Factory Default
50, 75, 110, 134, 150,
300, 600, 1200, 1800,
2400, 4800, 7200,
9600, 19200, 38400,
57600, 115200,
230400, 460800,
921600
This field specifies the baudrate for the serial port.
50 to 921600: The serial port will operate at the specified
baudrate
115200
Data Bits
Setting Description Factory Default
5, 6, 7, 8 This field specifies the number of data bits used to
encode each
character of data.
8
Stop Bits
Setting Description Factory Default
1, 1.5, 2 This field specifies the number of stop bits used for each
character frame.
1
Parity
Setting Description Factory Default
None, Odd, Even,
Space, Mark
This field
specifies the type of parity bit used for each character
frame.
None
Flow Control
Setting Description Factory Default
None, RTS/CTS,
XON/XOFF, DTR/DSR
This field specifies the type of flow control used by the serial
port.
RTS/CTS
FIFO
Setting Description Factory Default
Enable, Disable This field specifies whether the serial port will use the built-in
FIFO. A 128-byte FIFO is provided to each serial port for both
Tx and Rx directions. To prevent data loss during serial
communication, this should be set to Disable if the attached
serial device does not have a FIFO.
Enable
Interface
Setting Description Factory Default
RS-232, RS-422,
RS-485 2-wire,
RS-485 4-wire
This field specifies the type of interface the serial port will use.
RS-232