User`s manual
AWK-1121/1127 Web Console Configuration
3-37
Delimiter + 1 One additional character must be received before the data in
the serial port’s buffer is packed.
Delimiter + 2 Two additional characters must be received before the data in
the serial port’s buffer is packed.
Strip Delimiter
Data accumulated in the serial port’s buffer will be packed, but
the delimiter character(s) will be stripped from the data.
Force Transmit
Setting Description Factory Default
0 to 65535 This field controls data packing by the amount of time that
elapses between bits of data. When using this field, make sure
that Inactivity time is disabled or set to a larger value.
Otherwise the connection may be closed before the data in the
buffer can be transmitted.
0: If serial data is received, setting this value to 0 means no
data will be buffered and all data will be transmitted
immediately as received.
1 to 65535: If serial data is not received for the specified
amount of time, the data that is currently in the buffer will be
packed for network transmission. The optimal force transmit
time depends on your application, but it must be at least larger
than one character interval within the specified baudrate. For
example, assume that the serial port is set to 1200 bps, 8 data
bits, 1 stop bit, and no parity. In this case, the total number of
bits needed to send a character is 10 bits, and the time required
to tran
sfer one character is 8.3 ms, so the force transmit time
to be larger than 8.3 ms.
0 ms
Communication Parameters
The Communication Parameters page for the serial port is where serial communication settings are
specified, such as Baud rate, Data bits, and Stop bits.
The Communication Parameters page for the serial port is where serial communication settings are
specified, such as Baud rate, Data bits, and Stop bits.