User`s manual
AWK-1121/1127 Web Console Configuration
3-34
Packet Length
Setting Description Factory Default
0 to 1024 This field specifies the maximum amount of data that is allowed
to accumulate in the serial port buffer before sending.
0: Packet length is disregarded and data in the buffer will be
sent as specified by the delimiter settings or when the buffer is
full.
1 to 1024: Data in the buffer will be sent as soon it reaches the
specified length.
0
Delimiter 1 and 2
Setting Description Factory Default
Enable These fields are used to define special delimiter character(s) for
data packing. Enable Delimiter 1 to control data packing with a
single character; enable both Delimiter 1 and 2 to control data
packing with two characters received in sequence.
When these fields are enabled, serial data will accumulate in
the serial port’s buffer until the buffer is full or until the
specified delimiter character(s) are received. For example, the
carriage return character could b
e used as a delimiter in order
to transmit each sentence or paragraph in a separate packet.
Data will be packed according to Delimiter process.
Delimiters must be incorporated into the data stream at the
software or device level.
Unchecked
ATTENTION
When
Delimiter 1 is enabled, Packet length must be set to 0.
Delimiter Process
This field specifies how data is packed when delimiter characters are received. This field has no effect if
Delimiter 1 is not enabled.
Setting Description Factory Default
Do Nothing Data accumulated in the serial port’s buffer will be packed,
including delimiters.
Do Nothing
Delimiter + 1 One additional character must be received before the data in
the serial port’s buffer is packed.
Delimiter + 2 Two additional characters must be received before the data in
the serial port’s buffer is packed.
Strip Delimiter
Data accumulated in the serial port’s buffer will be packed, but
the delimiter character(s) will be stripped from the data.
Force Transmit
Setting Description Factory Default
0 to 65535 This field controls data packing by the amount of time that
elapses between bits of data. When using this field, make sure
that Inactivity time is disabled or set to a larger value.
Otherwise
the connection may be closed before the data in the
buffer can be transmitted.
0 ms