User`s manual
WE-2100T Series User’s Manual Web Console: System Management
9-17
System Management> System Settings> Digital IO
The Digital IO page is located under System Settings in the System Management folder. This is
where you configure the 9 built-in DIO channels.
DIO0 through DIO8
Default
Input (Mode), Low (State)
Options
Input, Output (for Mode)
Low, High (for State)
Description
This field specifies the mode and state of the DIO channel.
In "Input" mode, the DIO channel will operate as a digital input (DI) channel,
and the State setting will be disregarded. The channel state will be controlled by
the digital input device that is connected to the channel, such as a switch or a
button.
In "Output" mode, the DIO channel will operate as a digital output (DO)
channel. The State setting will control the channel's state, allowing on/off
control of a connected device such as an LED or alarm.
All DIO
Default
Input (Mode), Low (State)
Options
Input, Output (for Mode)
Low, High (for State)
Description
This field specifies the mode and state of all DIO channels, if desired. Any
setting that is selected will be applied to all DIO channels at once.
DIO Function
Default
Enable WLAN LED
Options
Enable/Disable WLAN LED
Description
This specifies whether the WLAN LEDs will be used. If enabled, DIO 4
through 8 will be reserved for use as WLAN LEDs. Manual settings for those
DIO channels will thus be ignored.