WE-2100T Series User’s Manual Web Console: Serial Port Settings
8-16
The Communication Parameters page is where serial communication settings are specified, such
as Baud rate, Data bits, and Stop bits.
Port Alias
Default
Options
free text (e.g., “Secondary console connection”)
Description
This is an optional free text field to help you differentiate one serial port from
another. It does not affect operation of the module.
ATTENTION
Serial communication settings should match the attached serial device. Check the communication
settings in the users manual for your serial device.
Baud Rate
Default
115200
Options
50, 75, 110, 134, 150, 300, 600, 1200, 1800, 2400, 4800, 7200, 9600, 19200,
38400, 57600, 115200, 230400, 460800, 921600
Description
This field specifies the baudrate for the serial port.
Data Bits
Default
8
Options
5, 6, 7, 8
Description
This field specifies the number of data bits used to encode each character of
data.
Stop Bits
Default
1
Options
1, 1.5, 2
Description
This field specifies the number of stop bits used for each character frame.
Parity
Default
None
Options
None, Odd, Even, Space, Mark
Description
This field specifies the type of parity bit used for each character frame.
Flow Control
Default
RTS/CTS
Options
None, RTS/CTS, XON/XOFF, DTR/DSR
Description
This field specifies the type of flow control used by the serial port.
FIFO
Default
Enable
Options
Enable, Disable
Description
This field specifies whether the serial port will use the built-in FIFO. A 128-byte
FIFO is provided to each serial port for both Tx and Rx directions. To prevent
data loss during serial communication, this should be set to Disabled if the
attached serial device does not have a FIFO.