User`s manual

WE-2100T Series User’s Manual Web Console: Serial Port Settings
8-14
Settings for UDP Mode
When Mode is set to UDP on the Operation Modes page, you will be able to configure additional
settings such as Destination address 1 through 4, Local listen port, and Delimiter 1 and 2.
Destination Address 1 to 4
Default
Options
IP address range and port (e.g., “192.168.1.1” to “192.168.1.64” and “4001”)
Description
In UDP mode, you may specify up to 4 ranges of IP addresses for the serial port
to connect to. At least one destination range must be provided.
The maximum selectable IP address range is 64 addresses. However, you can
enter multi-unicast addresses in the Begin field, in the form xxx.xxx.xxx.255.
For example, enter “192.127.168.255” to allow the module to broadcast UDP
packets to all hosts with IP addresses between 192.127.168.1 and
192.127.168.254.
Local Listen Port
Default
4001
Options
0 to 9999
Description
This field specifies the UDP port that the module listens to and that other
devices must use to contact the attached serial device.