User`s manual

WE-2100T Series User’s Manual Web Console: Serial Port Settings
8-9
Max Connection
Default
1
Options
1 to 4
Description
This field specifies the maximum number of connections that will be accepted
by the serial port.
1: Only a single host may open the TCP connection to the serial port.
2 to 4: This serial port will allow the specified number of connections to be
opened simultaneously. When multiple connections are established, serial data
will be duplicated and sent to all connected hosts. Data from hosts will be sent
to the attached serial device on a first-in-first-out basis.
TCP Port
Default
4001
Options
0 to 9999
Description
This field specifies the TCP port number that the serial port will use to listen to
connections, and that other devices must use to contact the serial port.
Delimiter 1 and 2
Default
Disabled
Options
Disabled, Enabled, 00 to FF
Description
These fields are used to define special delimiter character(s) for data packing.
Enable Delimiter 1 to control data packing with a single character; enable both
Delimiter 1 and 2 to control data packing with two characters received in
sequence.
When these fields are enabled, serial data will accumulate in the serial port’s
buffer until the buffer is full or until the specified delimiter character(s) are
received. For example, the carriage return character could be used as a delimiter
in order to transmit each sentence or paragraph in a separate packet.
Delimiters must be incorporated into the data stream at the software or device
level.