User`s manual
WE-2100T Series User’s Manual Serial Command Mode
13-10
Configuring Trigger Type
Serial Command Mode may be triggered by either software or hardware. You can set the trigger
type using Network Enabler Administrator, the Telnet console, the web console, or the serial
console.
With a hardware trigger, a signal received through DIO 0 will trigger the module to enter Serial
Command Mode. This is the default setting.
With a software trigger, a three-character sequence received through the serial port will trigger the
module to enter Serial Command Mode. When the software trigger is used, the highest achievable
data transmission rate will be 55000 bps. This is because all data received through the serial port
will be parsed. In other words, the system must continuously check the serial port data for the
trigger characters.
Disabling the trigger will disable Serial Command Mode.
ATTENTION
The default trigger type is hardware (DIO 0). Only one type of trigger may be active at a time;
hardware and software trigger may not be used at the same time.
Using Network Enabler Administrator
To use Network Enabler Administrator to configure the trigger type, you will need to find the
module and open its configuration window. Please refer to Chapter 12 for additional details.
The trigger type will be configured under the Serial CMD tab. Check the Modify and Enable
boxes to configure the trigger type.
When the trigger has been configured, click OK to save and restart the module with the new
settings.