Serial Device Servers >
General-purpose Device Server Selection Guide
NPort® 5610-8/16 NPort® 5610-8/16-48V NPort® 5630-8/16 NPort® 5650-8/16
NPort®
5650-8/16-M-SC
NPort®
5650-8/16-S-SC
LAN Interface
10/100BaseT(X) 1, RJ45 connector 1, RJ45 connector 1, RJ45 connector 1, RJ45 connector --- ---
100BaseFX --- --- --- --- 1, SC connector 1, SC connector
1.5 KV Magnetic
Isolation
√ √ √ √ √ √
Serial Interface
Number of Ports 8 or 16 x RS-232 8 or 16 x RS-232 8 or 16 x RS-422/485
8 or 16 x
RS-232/422/485
8 or 16 x
RS-232/422/485
8 or 16 x
RS-232/422/485
Connector 8-pin RJ45 8-pin RJ45 8-pin RJ45 8-pin RJ45 8-pin RJ45 8-pin RJ45
Communication
Parameters
Data Bits: 5, 6, 7, 8; Stop Bits: 1, 1.5, 2; Parity: None, Even, Odd, Space, Mark
Flow Control
DSR/DTR, RTS/CTS,
XON/XOFF
DSR/DTR, RTS/CTS,
XON/XOFF
XON/XOFF
DSR/DTR and RTS/CTS
(RS-232 only), XON/
XOFF
DSR/DTR and RTS/CTS
(RS-232 only), XON/
XOFF
DSR/DTR and RTS/CTS
(RS-232 only), XON/
XOFF
Baudrate 50 bps to 921.6 Kbps 50 bps to 921.6 Kbps 50 bps to 921.6 Kbps 50 bps to 921.6 Kbps 50 bps to 921.6 Kbps 50 bps to 921.6 Kbps
15 KV ESD Protection √ √ √ √ √ √
2 KV Optical Isolation --- --- --- --- --- ---
On-site Confi guration
LCD Panel with 4 push
buttons
√ √ √ √ √ √
Software
Network Protocols ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP, HTTP, SMTP, SNTP, ARP, PPP, SLIP, RTelnet, RFC2217
Confi guration Options Web Console, Telnet Console, Windows Utility
Driver Support
Windows Real COM driver (for Windows 95, 98, ME, NT, 2000, XP, 2003, Vista, XP x64, 2003 x64, Vista x64), Linux Real TTY driver, Fixed TTY driver (for SCO Unix,
SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i)
Operation Modes Real COM, TCP Server, TCP Client, UDP, Pair Connection, RFC2217, Reverse Telnet, Disabled, PPP
Physical Characteristics
Housing
SECC sheet metal (1
mm)
SECC sheet metal (1
mm)
SECC sheet metal (1
mm)
SECC sheet metal (1
mm)
SECC sheet metal (1
mm)
SECC sheet metal (1
mm)
Dimensions
440 x 45 x 198 mm
(17.32 x 1.77 x 7.80 in)
440 x 45 x 198 mm
(17.32 x 1.77 x 7.80 in)
440 x 45 x 198 mm
(17.32 x 1.77 x 7.80 in)
440 x 45 x 198 mm
(17.32 x 1.77 x 7.80 in)
440 x 45 x 198 mm
(17.32 x 1.77 x 7.80 in)
440 x 45 x 198 mm
(17.32 x 1.77 x 7.80 in)
Environmental Limits
Operating Temperature 0 to 55°C (32 to 131°F)
Operating Humidity 5 to 95% RH
Storage Temperature -20 to 75°C (-4 to 167°F)
Power Requirements
Input Voltage
100 to 240 VAC, 47 to
63 hz
±48 VDC (20 to 72
VDC, -20 to -72 VDC)
100 to 240 VAC, 47 to
63 hz
100 to 240 VAC, 47 to
63 hz
100 to 240 VAC, 47 to
63 hz
100 to 240 VAC, 47 to
63 hz
Power Consumption
141 mA @ 100 VAC, 93
mA @ 240 VAC
135 mA @ 48 VDC
152 mA @ 100 VAC, 98
mA @ 240 VAC
158 mA @ 100 VAC,
102 mA @ 240 VAC
174 mA @ 100 VAC,
113 mA @ 240 VAC
164 mA @ 100 VAC,
110 mA @ 240 VAC
Burst Protection
(EN61000-4-4: EFT/B)
4 KV 4 KV 4 KV 4 KV 4 KV 4 KV
Surge Protection
(EN61000-4-5)
2 KV 2 KV 2 KV 2 KV 2 KV 2 KV
Regulatory Approvals
EMC
CE (EN55022 Class A, EN55024), FCC Part 15 Subpart B Class A
NPort® 5610 only: IEC61000-4-12
Safety UL (UL60950-1), TÜV (EN60950-1)
Medical EN60601-1-2 Class B, EN55011
Marine DNV DNV DNV DNV DNV DNV
Reliability
Buzzer, Realtime Clock,
Watchdog Timer
√ √ √ √ √ √
MTBF
NPort® 5610-8: 97294
hrs
NPort® 5610-16:
94928 hrs
NPort® 5610-8-48V:
96758
NPort® 5610-16-48V:
94417 hrs
NPort® 5630-8:
118405 hrs
NPort® 5630-16:
91483 hrs
NPort® 5650-8:
117584 hrs
NPort® 5650-16:
104767 hrs
NPort® 5650-M-SC-8:
116914 hrs
NPort® 5650-M-SC-16:
87528 hrs
NPort® 5650-S-SC-8:
116914 hrs
NPort® 5650-S-SC-16:
87528 hrs
Warranty 5 years 5 years 5 years 5 years 5 years 5 years