Installation guide

8-30
www.moxa.com
info@moxa.com
8
Serial Device Servers >
NPort® 5600 Desktop Series
Serial-to-Ethernet Solutions
NPort
®
5600 Desktop Series
8-port RS-232/422/485 serial device servers
8 serial ports supporting RS-232/422/485
Compact desktop design
10/100M auto-detecting Ethernet
Built-in 15 KV ESD protection for all serial signals
Easy IP address con guration with LCD panel
Choice of confi guration methods: Web console, Telnet console,
and Windows utility
Versatile socket operation modes, including TCP Server, TCP
Client, UDP, and Real COM
SNMP MIB-II for network management
Built-in recorder: Use your own voice as the alert when excep-
tions occur
The NPort® 5650-8-DT device servers support selectable 1K-ohm and
150K-ohm pull high/low resistors and a 120-ohm terminator. In some
critical environments, termination resistors may be needed to prevent
the reflection of serial signals. When using termination resistors, it
The System LED, Serial Tx/Rx LEDs, and Ethernet LEDs (located on the
RJ45 connector) provide a great tool for basic maintenance tasks and
help engineers analyze problems in the field. The NPort® 5600’s LEDs
The NPort® 5600-8-DT device servers come with two Ethernet ports
that can be used as Ethernet switch ports. Connect one port to the
network or server, and the other port to another Ethernet device. The
The NPort® 5650-8-DT device servers support both a power terminal
block and power jack for ease of use and greater flexibility. Users can
NPort® 5600-8-DT device servers can conveniently and transparently
connect 8 serial devices to an Ethernet, allowing you to network
your existing serial devices with only basic configuration. You can
both centralize management of your serial devices and distribute
management hosts over the network.
is also important to set the pull high/low resistors correctly so that
the electrical signal is not corrupted. Since no set of resistor values
is universally compatible with all environments, NPort® 5600-8-DT
device servers use DIP switches to allow users to adjust termination
and pull high/low resistor values manually for each serial port.
not only indicate current system and network status, but also help field
engineers monitor the status of attached serial devices.
dual Ethernet ports eliminate the need to connect each device to a
separate Ethernet switch, reducing wiring costs.
connect the terminal block directly to a DC power source, or use the
power jack to connect to an AC circuit through an adaptor.
Since the NPort® 5600-8-DT device servers have a smaller form factor
compared to our 19” models, they are a great choice for applications
that need additional serial ports, but for which mounting rails are not
available.
The NPort® 5650-8-DT device servers support selectable 1K-ohm and
is also important to set the pull high/low resistors correctly so that
Convenient Design for RS-485 Applications
LED Indicators to Ease Your Maintenance Tasks
Two Ethernet Ports for Convenient Cascade-style Wiring
Convenient Power Inputs
Introduction
The certifi cation logos shown here apply to some or all of the products in this
section. Please see the Specifi cations section or Moxa’s website for details.