NPort® 5210/5210-T NPort® 5230/5230-T NPort® 5232/5232-T NPort® 5232I/5232I-T
LAN Interface
10/100BaseT(X) 1, RJ45 connector 1, RJ45 connector 1, RJ45 connector 1, RJ45 connector
100BaseFX --- --- --- ---
1.5 KV Magnetic Isolation
Serial Interface
Number of Ports 2 x RS-232 1 x RS-232, 1 x RS-422/485 2 x RS-422/485 2 x RS-422/485
Connector 8-pin RJ45 Terminal Block Terminal Block Terminal Block
Communication
Parameters
Data Bits: 5, 6, 7, 8; Stop Bits: 1, 1.5, 2; Parity: None, Even, Odd, Space, Mark
Flow Control RTS/CTS, DTR/DSR, XON/XOFF
RTS/CTS and DTR/DSR (RS-232
only), XON/XOFF
XON/XOFF XON/XOFF
Baudrate 110 bps to 230.4 Kbps 110 bps to 230.4 Kbps 110 bps to 230.4 Kbps 110 bps to 230.4 Kbps
15 KV ESD Protection
2 KV Optical Isolation --- --- ---
On-site Confi guration
LCD Panel with 4 push
buttons
--- --- --- ---
Software
Network Protocols ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP, HTTP, SMTP
Confi guration Options Web Console, Serial Console, Telnet Console, Windows Utility Web Console, Telnet Console
Driver Support
Windows Real COM driver (for Windows 95, 98, ME, NT, 2000, XP, 2003, Vista, XP x64, 2003 x64, Vista x64), Linux Real TTY driver, Fixed TTY driver (for SCO Unix,
SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i)
Operation Modes Real COM, TCP Server, TCP Client, UDP, Pair Connection, Reverse Telnet, Disabled
Physical Characteristics
Housing
Aluminum (1 mm), providing IP30
protection
Aluminum (1 mm), providing IP30
protection
Aluminum (1 mm), providing IP30
protection
Aluminum (1 mm), providing IP30
protection
Dimensions
67 x 100.4 x 22 mm
(2.64 x 3.95 x 0.87 in)
67 x 100.4 x 22 mm
(2.64 x 3.95 x 0.87 in)
67 x 100.4 x 22 mm
(2.64 x 3.95 x 0.87 in)
67 x 100.4 x 35 mm
(2.64 x 3.95 x 1.37 in)
Environmental Limits
Operating Temperature Standard Models: 0 to 55°C (32 to 131°F); Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Operating Humidity 5 to 95% RH
Storage Temperature -20 to 85°C (-4 to 185°F)
Power Requirements
Input Voltage 12 to 48 VDC 12 to 48 VDC 12 to 48 VDC 12 to 48 VDC
Power Consumption 305 mA @ 12 V max. 347.1 mA @ 12 V max. 259.6 mA @ 12 V max. 509.4 mA @ 12 V max.
Burst Protection
(EN61000-4-4: EFT/B)
1 KV 1 KV 1 KV 1 KV
Surge Protection
(EN61000-4-5)
0.5 KV 0.5 KV 0.5 KV 0.5 KV
Regulatory Approvals
EMC CE (EN55022 and EN55024 Class A), FCC Part 15 Subpart B Class A
Safety UL (UL60950-1), TÜV (EN60950-1)
Medical EN60601-1-2 Class B, EN55011
Marine DNV DNV DNV DNV
Reliability
Buzzer, Realtime Clock,
Watchdog Timer
MTBF 134850 hrs 106955 hrs 102344 hrs 87083 hrs
Warranty 5 years 5 years 5 years 5 years