User`s manual

VPort P06-1MP-M12 EN 50155 IP Camera Introduction
1-6
Solid plastic top cover: This top cover can be removed when tuning the camera lens position.
Transparent dome cover: The VPort P06-1MP-M12 is designed with a transparent PC dome cover, which
is vandal-proof with EN 62262 (IEC62262) class IK8 level protection.
Torx screw for top cover: There are 2 torx screws for the top cover. These 2 torx screws are designed
with anti-shedding for convenient installation. The user can use the L-type torx screw driver for loosening
or fixing the top cover.
NOTE
The color of the camera casing can be customized based on your installation environment. Please contact your
Moxa sales representative for this
customization service.
Inside the camera
Mounting screw hole: There are 4 mounting screw holes for mounting the VPort P06-1MP-M12.
Thumb screw for fixing the lens position: To tune the lens’s position, loosen this thumb screw. After
the position tuning is done, secure this thumb screw.
Lens with fixed focal length: The VPort P06-1MP-M12 is designed to use different fixed focal-length
lenses. Choose the appropriate focal-length lens based on the viewing angle and object distance of your
application.
Hardware reset button: Use a pointed stick to push down the reset button to reboot or restore factory
defaults.
Reboot: press the button one time.
Reset to factory default: press the button and hold for at least 5 seconds.
Calibration for rotating the lens (0 to 360°): Rotate the lens to get the optimal image, and then mark
the position with this calibration for future replacement or mass installation.
Calibration for tuning lens’s vertical position (0 to 90°): After tuning the lens’s vertical position,
mark the position with this calibration for future replacement or mass installation.
Calibration for tuning lens’s horizontal position (±30°): After tuning the lens’s horizontal position,
mark the position with this calibration for future replacement or mass installation.