User`s manual
VPort 36-1MP System Configuration
4-23
Trap Settings
Setting Description Default
Trap Server
IP/Name
Enter the IP address or name of the Trap Server used by your
network.
No
Trap Community Use a community string match for authentication; Maximum of
30 characters.
No
Private MIB information
The private SNMP Object ID of the VPort is the enterprise value: 8691.8.4.2. This number cannot be changed.
NOTE
The MIB file is MOXA
-VPORT16-M
IB.mib (or.my). You can find it on the software CD or the download center of
the Moxa website.
Modbus/TCP
Modbus is a serial communications protocol which is often used to connect a supervisory computer with a
remote terminal unit (RTU) in supervisory control and data acquisition (SCADA) systems. To transmit Modbus
over a TCP/IP network, a standard Modbus/TCP protocol is provided. With the support of the Modbus/TCP
protocol, the SCADA/HMI system can directly communicate with the VPort to acquire its operational status.
Setting Description Factory Default
Enable Modbus/TCP
Enable the Modbus/TCP protocol
Enable
NOTE
For Modbus
address table, please refer to the Modbus_Address_Define.pdf. You can find it on the software CD
or the download center of the Moxa website.
Video
Image Settings