User`s manual
SoftDVR™ Lite/Pro User’s Manual Application Settings
4-19
SendMail: Send an alarm e-mail (refer to General Setting section for information on setting
up the e-mail system).
Alarm Notify: Play a WAV sound of your choice to notify users
Recall Preset: Move PTZ-enabled camera to preset position to monitor and record—If a
camera is equipped with the PTZ function, and its preset position has been set up,
administrators can establish the interactions between alarms and the PTZ camera.
DO1 and DO2: Trigger digital output device such as alarm light—Moxa VPort Series Video
Servers can connect to DI/DO devices,and administrators can set up DO conditions to trigger
actions by selecting Normal Open or Normal Close of VPorts.
NOTE
To set up DI/ DO operations, administrators can click on Digital I/O Status to see the current
status of the DI, and reset the DO status by clicking on Open and Close.
4. Administrators can input some descriptions to explain this alarm in Alarm Remark. After all
of the settings are done, click on New/Modify to add this new alarm to the list. Click on Clear
to re-build the new alarms. Click on OK to save the settings and return to the Main Window.
At this point, the alarm system will be on.
Modifying an Alarm’s Settings
1. Select the alarm from the list.
2. Change the settings.
3. Click on New/Modify to modify. Click OK to save the settings and return to the Main
Window.
Removing an Alarm
To remove an alarm from the list, select the alarm and click on Remove to delete it.