User`s manual

VPort D351 User’s Manual Technical Specifications
Alarm
System Alarm
In addition to the LED indicators, two kinds of system alarm are provided by the VPort D351 for
notifying the system administrator.
Alarm Type Triggered Condition Triggered Action
Power Failure
1. Power 1 failure
2. Power 2 failure
1. Relay
2. Email
Network Disconnected
Network disconnected Relay
Power Failure Alarm
Setting Description Default
Enable power failure
alarm
Enable or disable power failure alarm. Disabled
Power 1 Failure/Power 2 Failure
Setting Description Default
Trigger Relay alarm
Enable or disable the alarms to trigger
either Relay 1 or Relay 2.
Disabled
Auto warning via
recipient email
Enable or disable sending warning
messages via the recipient’s email;
configuration is done on the Network Æ
SMTP Server page.
Disabled
Network Disconnected Alarm
Setting Description Default
Enable network
disconnected alarm
Enable or disable network disconnected
alarm.
Disabled
Trigger Relay alarm
Enable or disable the action in triggering
Relay 1 or Relay 2 alarms.
Disabled
A-22