V2416 Series Software Configuration
2-13
When a new hard disk is inserted, the system will automatically detect the hard disk and have it plugged into
the system.
Handle the LED action: The LEDs are blinking when the hard disks are writing or sending data.
Handle the disk capacity action: When the storage use exceeds the limit set in the customizable settings,
the LED will continuously blink to notify the user. The default setting is 90% disk utilization.
If you would like to change the disk capacity notification threshold, edit the file mxhtspd.conf under
C:\Program Files\MOXA\mxhtsp\config and enter the new value:
Configuring the Disk Drive Letters for Disk Removal
The default drive letters are Disk D and Disk E. Disk D refers to the disk drive installed in the Disk 1 slot, and
Disk E to Disk 2 slot. If you need to insert only one disk, we suggest you insert it in the Disk 1. However, you
may still insert the disk in the Disk 2. If it happens, we strongly suggest you change the disk drive letter in the
mxhtspd setting so that it will not affect the function when you push the LED to remove the disk. To do so,
follow the instructions below: