User`s manual

UC-8410/8416/8418-LX User’s Manual Managing Embedded Linux
3-5
Loading Factory Defaults
Press the reset button for more than 5 seconds to force the system to load the factory default
settings. All files in the /home, /etc, /usr/local/bin, /usr/local/sbin, /usr/local/lib, /usr/local/libexec,
and /tmp directories will be deleted. While pressing the reset button, during the first 5 seconds the
ready-light will blink once each second. If you continue pressing the button after 5 seconds have
passed, the ready-light will turn off, indicating that the factory defaults have been loaded.
ATTENTION
Reset-to-default will erase all data stored in /dev/mtdblock4
If you have stored data in the writable partition, you will need to back up these files before
resetting the system to default. On the UC-8410/8416/8418, the directories /tmp, /etc,
/usr/local/bin, /usr/local/sbin, /usr/local/lib, /usr/local/libexec, and /home are mounted on
/dev/mtdblock4. This means that all of the data stored in these directories will be destroyed after
resetting to default.
Enabling and Disabling Daemons
The following daemons are enabled when the UC-8410/8416/8418 boots up for the first time.
snmpd SNMP Agent daemon
telnetd Telnet Server / Client daemon
inetd Internet Daemons
ftpd FTP Server / Client daemon
sshd Secure Shell Server daemon
httpd Apache WWW Server daemon